Pilot light will not stay lit when water is hot


The pilot light goes out when the burner has heated the water. In the morning, I can light the pilot by pushing the button down and striking the electric igniter. But, once the burner turns off, the pilot can be lit by pushing the button down but it goes out the second the button is released. The pilot looks the same when the water is cold and will stay lit and when the water is hot and it won't stay lit. What is your make and model hot water heater. I have $1.00 that says its a AO smith. If so I can help. Even if its not a AO smith I can still help, but I need the make and model. Mike NJ Its a Ruud Pacemaker series 50 gallon residential gas water heater. What year is the HWH? It may be under warranty and you may just need to pay labor. These have several saftey devices if its newer. 1. May be t couple. Might be loose at gas valve or sporadic failure. 2. The gas valve may be defective and fails ony on temp rise. The gas valve also has a part to play with the pilot. Is the water abnormally HOT???? 3. Combustion Shutoff Device Tripped.( possible resets itself) There is another feature that is a one time use item, but you would not be able to relight. #3 is a door that closes to not allow air in the combustion chamber. These HWH are not homeowner friendly. With this new technology installing in a dusty enviroment, like by a dryer often causes issues such as this. I suggest you call Rudd and get a tech to look at it. I could tell you take the burner apart but I advise against it. These are sealed chambers and need to be assembled correctly for saftey reasons. Mike NJ I have an ao smith GVR 50 water heater, 5 years old, pilot will not stay lit. Cleaned intake screen, still won't stay lit. What is next? Next step is usually to replace the thermocouple. If your pilot is bathing the thermocouple in flame, and the pilot goes out when you release the start button or turn the dial from pilot to normal run, the thermocouple probably needs replacing. I have an ao smith GVR 50 water heater, 5 years old, pilot will not stay lit. Cleaned intake screen, still won't stay lit. What is next? What is the series # of the unit? These have FVIR technology. The t couplers are part of a whole burner assembly. If you can give me the serial # I can check for you. I was a AO Smith rep. Mike NJ I had an issue where the pilot would not turn on under any condition. I replaced the thermocouple assembly and gas valve (thermostat) so now the pilot will light and stay on until I move the selector from pilot to on, but once the water in the tank is hot the burner and pilot extinguish completely. The following day I had to do the same thing. Is there a setting or gap on the thermocouple or anything I missed? What is the make and model heater? What is the serial #. Mike NJ I believe it is a AO-GCV50 (Promax 50 gallon residential). The gas valve part number was 182791-006 is now 9000249005. I replaced it and the thermocouple assembly. I appreciate your help! I am not home at the moment, but I can take a lunch to get the serial number if you need it. what year is it do you think? This way I know what FVIR technology it has. Mike NJ The year of the model is 2005 Just verify series 100 correct? It has a corderite disk and it need cleaning if so but I want to make sure. Is the unit by a dryer or furnace? Mike NJ Yes, it is the 100 series. I replaced the gas valve with the 200 series per the vendor because the 100 had too many problems. The unit is in my garage in an elevated area specifically built for the water heater. I have no other appliances or fuels stored near it. I have enough clearance to walk to and from it and the garage is ventilated (although no breeze comes through). I am not familiar with the corderite disk. Is this the same as the ceramic flame arrestor that is part of the FVIR? If so, it would make sense for me to remove the thermocouple assembly again and find a way to clean the area out. Are there specific cleaing instruction for this unit? The gas valve thermostat came with a very wide filter that I have no idea or even where to install. I looked inside the chamber to see if it had one so I'd get a clue, but I didn't see anything like it. I am confident enough to do the work, but I just need some instruction. Thanks again! On the bottom of the water heater there is a black lint screen. remove this and get a bright flashlight. Look in the slots and look up on the under side. There is the disk. Air comes in and goes through there for the burner. Does it look like a layer of lint is there? Let me know and I will instruct you further. By the way its not the t couple. There is a high temp thermistor that is in line with the t couple. If you changed the t couple with a stote bought one then you put yourself at risk. When these units starve for air it affects the draft and CO poisoning can occur. Basically you can be dead. These devices reset when the heater cools down below 180C-210C. But it trips for a reason. I advise to to shut the unit down if you have done this. You have by-passed a saftey feature. Let me know. Mike NJ I purchased the entire t couple assembly at an authorized AO Smith dealer (Ferguson Enterprise), not a hardware store. It is the PSW12204 pilot assembly if that means anything to you. I just checked the black air intake lint screen which was surprisingly clean, but I removed a little surface dust. I will inspect and clean the radiation shield and flame arrestor in the near future. I'm missing the flexible brush that was supposed to come with the unit, but I will vacuum inside if I can. I believe I have a FVIR type C3 by the way. Let me know I will be here for another hour or so. What does it say on the tag on the orange wire from the igniter? Mike NJ The one I removed says 180○C 183828-180 760-312. New one says 200○C 183824-200 760-312 New one says 200○C OK good. Thats the ungraded pilot assembly AO smith new there was a issue so they raised the temp on the thermistor. If you have your old assembly, its that little round fuse thing in line with the t couple. OK if you looked in the air vent and up, you probably seen a thin or thick layer of dust? You need to vacuum that. How do you do that you ask? What I do is get 2 ft of 1/2 copper. Put a ellbow on the end. Get your shop vac and insert the copper end in the vac hose and duct tape it good. What you made is a vac tool. Turn on the vac, and make sure you got good suction from the ellbow. Stick it in the air vent, get the ellbow facing up and vacuum that disk real good. Its about 10 round and you should feel the edge as you vacuum. Let me know. Here is some good stuff for ya. They say use a brush but I find a vacuum works better. http://www.hotwater.com/lit/fvirtechbulletin.pdf Mike NJ I was able to get in there a little with a vac, but not nearly as well as I wanted. It appeared to be fairly clean as I found a long delicate brush to gently go over it with, but I want to do a better job with the vacuum. I reassembled everything I think better than before then relit the pilot and it stayed on with no problem. As I adjusted the temperature to warmer temps (between B C) the burner finally kicked on. I am going to have to wait to see if this did the trick for now. I will check in with you tomorrow or the following day. I am definitely going to build myself one of your vacuum tools. Did you ever try using PVC? I'm asking because it's more readily available on this side of the planet. Mike, you are a great help and amazingly creative! I'll talk to you in a few days kind sir. I am definitely going to build myself one of your vacuum tools. Did you ever try using PVC? I usually use 3/4 copper but you need to cut the ellbow so it will fit when you turn it up to vacuum the under side of the disk. You will see what I mean when you do it. I was going to make a tool and patent it, but AO smith stopped making this series. Its a 200/201 series now with different technology. What happens is that disk gets clogged and the burner starves for air. The unit does not draft and the flame starts burner down towards the air. It gets close to the thermister that trips at 200C. This shuts the gas off. When it cools down you will be able to re-lite the unit but it will keep happening until you fix the air issue. AO smith use to have the only resettable thermister. They have a button on the front by the burner window now. The other companys had a fusible link in the t couple. Once they tripped you would need a whole new pilot assembly every time. These where home store models. AO smith is ahead of everyone and most adapt the technology from them. Mike NJ You should still patent it.. I'd still buy one. I understand your articulate explanation and appreciate your patience and willingness to teach. Interesting history behind the technology. Today I took the hottest shower in quite a long, long time. I think the issue is resolved because I can turn the thermostat down and I can hear the roaring flame stop and then start up again when I turn it up again. It wasn't doing that before. I would have to relight it. I am still going to clean it in a week or so. I'll see if I can find 3/4 copper tubing this weekend. I can't tell you enough how much I appreciate your help! Thank you. Your welcome. Glad I can help. Mike NJ I have AO Smith Promax 40(gallon) 100(series) and I ran into the same problem with the pilot light being blown out when the unit turns on itself to heat the water. I hear a loud poof noise and then the pilot light is out, as if being blown out forcefully. It all happened when a guest is trying to use my upstairs bathroom tonight and there is no hot water upstairs (I don't know how long it has been that way since we rarely go upstairs ourselves). I went to check on the water heater unit in my garage that feeds upstairs and saw the pilot light is not lit. I followed the instructions on the water heater and lit the pilot, it came on fine and started to heat the water. I left it like that and waited half an hour, there is hot water upstairs! Went back to the water heater to replace the cover on the bottom, and saw the pilot light is out again. I re-lit the pilot following the instructions, I guess since the water is still hot so I did not hear the sudden rush of gas and the pilot light stayed on. I waited there for about 5-10 minutes to see if the water heater will start heating itself once the water cools down a little. And when it did you can hear the loud hoosh of gas or fire going up inside the unit like its about the do some major 'heating', but the pilot light goes out quickly like being blown out (with a poof sound) and everything goes quiet. I waited a few minutes and re-lit the pilot a third time. Its been an hour now and the pilot light is still lit... I wonder if this is going to happen again? I am definitely interested to check tomorrow morning to see if the pilot is still lit. If it is out again, should I shut off gas to the unit and call for service? Is this a defective part issue? Malfunctioning? Or needs to be cleaned? Your input is greatly appreciated! Your pilot lights and your burner flames up so it seems like it may be the same type of issue of just having to clean the unit. I'm not an expert so I'll see what a second opinion or expert would say. I wonder if this is going to happen again? I am definitely interested to check tomorrow morning to see if the pilot is still lit. If it is out again, should I shut off gas to the unit and call for service? Is this a defective part issue? Malfunctioning? Or needs to be cleaned? Read my posts below. #13 and up. Also the link I posted. The disk is clogged and the unit is starving for air. It trips a thermister when the burner is on, because the flame rolls down looking for air and overheats the thermister. Make a tool and vacuum the underside of the disk as I described. If you call a professional they most likely will want to sell you a new heater. Most plumbers (service techs) dont know about the new technology and have no clue on troubleshoot or repair them. Most are parts changers and they get paid by the revenue they produce. So to come in your home and vacuum your heater is not what a typical tech will offer. It makes no money. This is why I am not in the trade any longer. Cant rip people off in the tuff economy. Mike NJ Hi Mike, Thanks for all of your good info. I have an aosmith promax xclv 30 100. pilot wont stay lit, tried cleaning arrestor holes to no avail, have had plumber in twice, he's apparently not online saavy and i feel like i've done so much research on this problem over the 3 weeks i've not had hot water that i know more about the thing than he does.,., ANYway, i'm looking to see if its ok to just remove the glass window from the sealed chamber to allow more air flow. is the sealed chamber a safety measure keeping flame in/combustion air out in case of outside vapors? i keep nothing vaporous/flamable around the unit. I know the stupid thing works, i can get it to stay lit intermittently and its only 6 yrs old,,,, i have an older model, w/o the fvir sys, in another home and it still works fine,,,,,, i feel like i just want to open the sealed chamber so it will work like the older models... is this thinking correct? I am not a plumber but am frustrated to have to replace the whole unit when i see it working from time to time Hi. Thats a 10 yr water heater. You should not have to fix anything regarding parts or tank. You only need to pay labor. 1. If the pilot does not stay lit you need a pilot assembly. Its covered under warranty, and you pay labor. Should be around $99. 2. If the pilot light goes out sporatically, but you are able to light it, it a clogged disk most likely. Read my posts below. tried cleaning arrestor holes to no avail, Did you read my links below??? Arrestor holes? Its a ceramic disk. If you take the black lint screen off from the bottom of the heater, then lay your head real low on the floor and look up in the lint screen opening. See a layer of dust? That needs to be vacuumed. You need to make a tool to get in there. AO smith should change the pilot assembly anyway since they went from a 180celcius thermistor to a 200c. And the guy that comes out should know all this. Look at the tag on the orange wire. Whats it say? 180c, 190c, 200c? But if you call AO smith, they will give you the correct plumber to call in your area that repairs them under warranty, and should know clean the disk. You cant just use a plumber off the street. Open this link and click on the top where it says heater info. Put in your info then call AO smith. This is for ao smith, state, etc... ( any ao smith product ) https://warranty.hotwater.com/default.aspx ANYway, i'm looking to see if its ok to just remove the glass window from the sealed chamber to allow more air flow. is the sealed chamber a safety measure keeping flame in/combustion air out in case of outside vapors? i keep nothing vaporous/flamable around the unit. I know the stupid thing works, i can get it to stay lit intermittently and its only 6 yrs old,,,, No, no, no. Do not by-pass any saftey device. I was a rep for AO smith. Mike NJ Um i'm sorry that seemingly based on my post youre assuming I havnt read up or performed any of what you suggested. I mentioned in my post that I cleaned the ceramic flame arrestor holes. Cleaned it according to the vid sent to me by aosmith: Standard Gas Control Water Heaters - Filter Cleaning ">








Related Posts:




  • Pilot light wont light ao smith

    pilot light wont light AO SmithHello all, I have an AO Smith gas water heater and the pilot light wont light. GCV 50 200 Build date 10/ 27/ 2009 I followed directions, push gas control nob down in...


  • Pilot light still wont stay on after changing thermocouple

    Pilot light still won't stay on after changing ThermocoupleHi guys, 3 days ago I tried to turn on the pilot light and it won't stay on. So I googled and figured it's probably the thermocouple. Yes...


  • Pilot light on gas logs wont stay lit with logs on

    Pilot light on gas logs won't stay lit with logs onWe have just purchased vent free gas logs; with the logs off the pilot light will stay lit and the flame will work; with the logs on the pilot li...


  • Pilot light problem on a carrier gas furnace

    Pilot Light problem on a Carrier Gas furnace[SIZE=3]I have a carrier Gas Furnace that has a problem with the pilot light. I will try to describe the problem. It has an automatic pilot igniter. Som...


  • Pilot light goes out on gas fireplace after switch turned to on position

    Pilot light goes out on gas fireplace after switch turned to on positionI followed the instructions to light the pilot on my FP. (pushed pilot dial in, turned it to Pilot, pushed in ignitor button...