Hot water baseboard vs steel panel radiators cost analysis

Hot Water Baseboard vs. Steel Panel Radiators cost analysis


I am having a modular house built and the heating contractor has given me the option of using hydronic baseboard heating or hydronic, European style steel panel radiators made by Radson. He has clearly explained the advantages of the wall radiators in terms of efficiency when using a condensing boiler but the cost difference is $8000. I am trying to determine whether the advantages are worth the cost difference. There is no way we can tell you if the advantages are worth the cost differences with out. Heatloss of house. Sizing of the steel rads (ie design water temp) Your location. Need approximate bin data for your area. The one advantage to the steel rads is thermal mass, and that creates a more even comfortable home. Finned BB can lose effectiveness once they start getting blocked with dust. Since they operate at a higher temp and heat the air, not radiant and convetion as do panel rads you tend to feel them more. There is a new line of BB that will operate at very low temps, like 90 to 100 degrees. They will also be expensive too. Thanks for your response. I have some of the data that you have mentioned. In terms of heat loss, the total BTUH (I believe this is annually) is 65,239.68 based on 8500 heating degree days and a 90 degree heat design difference. The design water temp per the contractor is 120-130 degrees. I live in northern New England (Hanover, NH). I researched Bin data on the internet and am having some difficulty with the concept and cannot find data on my location. However, I guess I am also interested in anyone's generic thoughts on whether the increased cost is worth the advantage of steel panel radiators (i.e. whether the difference in comfort, efficiency, etc is only slight or large). The heating contractor is very pro radiators. 65k BTU/hr is the design day heat loss per hour. Design day in Hanover is probably around -5 to -9 F. Seems pretty lossy for new construction. How many square feet? Water temps in the 120-130 F range will allow productive condensing from a condensing boiler. If properly controlled and zoned, it should work well. As TO mentioned, there's no way we can know what premium you place on comfort. The rads provide comfortable, even radiant heat. Fin-tube is principally convection. However, a well-controlled fin-tube system using constant circulation is pretty darn good too. If you can oversize the baseboard (by length or output per foot) and still use condensing temperatures for all but the most extreme conditions, that might be a good compromise. But it's your call.


Related Posts:




  • Hvaccalc says i have heat loss of 46000 btuh

    HVAC-CALC says I have heat loss of 46000 btu/hAfter having played with hvac-calc to get an idea of my heat-gain i decided to look at the heat loss. it claims I have heat loss of about 46000 BTU/h....


  • How to install hot water baseboard heating

    Install Hot Water Baseboard HeatingI converted part of my garage to a living room, and I'm up to the heat. I have a 5 room ranch(now 6), w/ 1 zone of hot water baseboard heating. Can you tell me w...


  • Gas hot water heater timer

    gas hot water heater timer?Is there such a thing as a gas hot water heater timer? Wife loves to turn the t-stat to hot, then goes to work and the water heater just keeps boiling the water all day...


  • Electric baseboard heaterhydronic or not

    Electric Baseboard Heater:Hydronic or Not?If I were to buy new electric baseboard heaters to replace existing ones in my family room addition, would there be any substanial savings in electric cos...


  • Is anyone familiar with lochinvar knight problem with heatmod rate

    Is anyone familiar with Lochinvar Knight? (problem with heat/mod rate)Hi everyone, I have a Lochinvar Knight (KBN080) boiler that was installed this past summer. It has an outdoor reset and as suc...